Industrial Fireproof Rolling Door Motor for Fire Rated Shutters

  • Automatic Phase-Sequence Correction: Automatically corrects reversed 3-phase wiring, eliminating manual phase swapping and preventing reverse motor rotation during commissioning.

  • FACP Fire Alarm & Remote Linkage: Seamlessly integrates with building Fire Alarm Control Panels and firefighting systems to trigger automatic emergency closure.

  • Double-Track Double-Curtain Compatible: Specially configured to power standard steel fire shutters as well as complex dual-track/dual-curtain fire safety assemblies.

  • Complete Fire Safety Control Package: Includes the FJK-M-QL06 dedicated controller, electronic limit control, dual manual control stations, and a 3-year warranty backup battery system.

Share:

Industrial Fire Safety Drive System

ANLIN Industrial Fireproof Rolling Door Motor

3-Phase AC Fireproof Rolling Shutter Drive Package with Automatic Phase-Sequence Correction

Automatic Phase Correction
FJK-M-QL06 Controller Included
Double-Track Double-Curtain Compatible
Backup Battery System (3-Yr Warranty)

The ANLIN Industrial Fireproof Rolling Door Motor is designed for industrial and commercial fire-rated rolling shutters, including steel rolling doors and double-track, double-curtain fire shutter systems.

The motor uses 3-phase AC power and incorporates automatic phase-sequence correction. If the incoming phase sequence is reversed, the controller corrects it automatically, so installers do not need to swap the power phases manually during commissioning. This is particularly useful on projects where the motor is installed as part of a larger fire shutter or building fire protection system.

The drive system is supplied with the FJK-M-QL06 fireproof rolling controller, electronic limit control, dual manual control stations, a backup battery system, and flexible metal conduit for protected wiring. The controller can receive signals from a building fire alarm or firefighting control system and can be configured for remote or network control according to project requirements.

For manufacturers, fire protection contractors, door installers, and distributors, the motor can be supplied as a complete control package or configured according to shutter design and installation requirements.Industrial Fireproof Rolling Door Motor

Automatic Phase-Sequence Correction for 3-Phase Power

One practical feature of this 3-phase fire shutter motor is the automatic phase-sequence correction function.

With a conventional three-phase motor, an incorrect phase sequence can cause the motor to rotate in the wrong direction. The installer normally has to identify the problem and exchange two phase wires before commissioning the door. The ANLIN control system handles this automatically.

How It Works: When the incoming three-phase sequence is detected as incorrect, the controller adjusts the phase sequence so that the motor operates in the required direction. This removes the need for manual phase swapping during installation.

For contractors working on multiple fire-rated shutters at a warehouse, factory, logistics center, or commercial building, this can make commissioning more straightforward, especially where the power supply has already been connected by another electrical contractor.

Electronic Limit Control

The motor uses electronic limit positioning instead of a conventional mechanical limit arrangement.

The limit function controls the required upper and lower operating positions of the rolling shutter. Once the limits have been set during commissioning, the controller uses the stored positions to control the opening and closing movement of the door. This arrangement is suitable for fire-rated rolling shutters where accurate door positioning is required as part of the overall installation.

The electronic limit system is also integrated with the control box, allowing the installer to set and check the operating positions without relying on a traditional mechanical limit adjustment method at the motor.

For replacement projects, the limit configuration can be reviewed together with the shutter dimensions, motor arrangement, and control requirements before production.

FJK-M-QL06 Fireproof Rolling Controller

The FJK-M-QL06 Fireproof Rolling Controller is the main control unit supplied with the motor package. It handles motor operation, fire signal input, electronic limit control, manual controls, and related control functions.

The controller can be connected to the building’s fire protection system where required. When the specified fire signal is received, it activates the programmed shutter closing operation.

For projects using centralized fire alarm control, the controller provides the connection point between the fire shutter motor and the external fire control system. Remote control or network control can also be configured where required by the project. Using a dedicated controller also makes the electrical arrangement easier for installers to identify during commissioning and later maintenance.

Fire Alarm and Remote Control Integration

Fire-rated rolling shutters are often part of a larger fire compartmentation system rather than operating as independent doors. The ANLIN motor control package can accept the required signal from a Fire Alarm Control Panel (FACP) or other compatible firefighting control equipment.

Under the specified alarm condition, the controller initiates the shutter closing sequence. The system can also be configured for:

■ Fire alarm signal input
■ Central firefighting control
■ Remote control
■ Network control
■ Manual wall-mounted control stations

The exact connection method depends on the project control design and the equipment used by the building’s fire protection system. For new construction projects, we recommend confirming the control signal type and interface requirements before production so that the motor and controller configuration can be matched to the site system.

Shutter Compatibility & Manual Control Stations

Double-Track Double-Curtain Fire Shutter Compatibility

The motor is suitable for double-track, double-curtain fire shutter systems, also commonly described as dual-track and dual-curtain fire shutters. These systems use two curtain assemblies within a fire-rated opening and are commonly specified where the door design requires a double-curtain arrangement.

The motor and control system provide the lifting and controlled closing functions required by the shutter assembly. Before production, the motor configuration should be checked against the door dimensions, curtain arrangement, shaft or mounting structure, and control requirements.

Dual Manual Control Stations

The standard control package includes dual wall-mounted manual control stations. These controls provide local operation of the fire shutter during installation, testing, commissioning, and normal service conditions where manual control is permitted by the project design. The manual stations are connected to the main controller and work together with the electronic limit and automatic control functions.

Technical Specifications

Specification Technical Detail
Product Type Industrial Fireproof Rolling Door Motor
Application Fire-Rated Rolling Shutters
Door Material Steel / Galvanized Steel
Power Supply 3-Phase AC
Phase Correction Automatic Phase-Sequence Correction
Limit Control Electronic Limit Positioning
Controller FJK-M-QL06 Fireproof Rolling Controller
Manual Control Dual Wall-Mounted Push-Button Stations
Backup Power Backup Battery System
Battery Warranty 3 Years
Wiring Protection Flexible Metal Conduit Hose
Fire Control Interface Fire Alarm / Firefighting Control Signal Input
Remote Control Available According to Configuration
Network Control Available According to Project Requirements
Door Configuration Standard and Double-Track Double-Curtain Systems

Typical Applications

The industrial fire shutter motor is intended for fire-rated rolling door installations in industrial and commercial buildings. Typical applications include:

■ Warehouses and logistics centers
■ Manufacturing plants
■ Industrial workshops
■ Commercial buildings
■ Fire compartment openings
■ Large industrial door openings
■ Double-track double-curtain fire shutters
■ Steel and galvanized steel fire-rated rolling shutters

Installation & Project Selection Checklist

The correct motor configuration depends on more than the door opening size. Before confirming an order, ANLIN can review the main project information, including:

■ Clear Opening: Width and height
■ Curtain Specs: Curtain type, construction & approximate weight
■ System Arrangement: Single or double-curtain arrangement
■ Power & Interface: Power supply & fire alarm interface
■ Control Options: Manual control, remote control or network control requirements
■ Installation Setup: Motor mounting position & site wiring arrangement

* For engineering projects, drawings or basic door specifications can be provided for technical review before production. This is particularly important for double-track double-curtain fire shutters.

Supply Options for Manufacturers and Contractors

ANLIN can supply the motor as a complete fire shutter drive and control package. The standard package includes:

1. Fireproof rolling door motor
2. FJK-M-QL06 fireproof rolling controller
3. Electronic limit control
4. Dual manual control stations
5. Backup battery system
6. Flexible metal conduit hose
7. Related mounting and connection components

For door manufacturers, fire protection contractors, and distributors, component configuration can be discussed according to shutter design and project requirements. If replacing an existing door motor system, please provide original motor info, door dimensions, curtain weight, and control requirements for technical checking.

Manufacturing & Quality Control

Fujian Anlin Intelligent Science and Technology Co., Ltd. manufactures fire shutter and fire protection equipment for industrial and commercial applications.

Production and inspection procedures cover the motor assembly, controller, electrical connections, mechanical components, and completed control package before shipment. The company operates under an ISO 9001 quality management system and provides products for overseas building, industrial, and fire protection projects.

For volume orders, production planning can be arranged according to required configuration and delivery schedule. The stated production capacity for standard configuration is up to 300,000 units per month. Overseas customers can confirm configuration, controller requirements, packaging, quantity, and delivery schedule with the ANLIN sales team prior to order placement.

Frequently Asked Questions

✔ Q1: What type of power supply does this fire shutter motor use?

The motor is designed for 3-phase AC power. The control system also includes automatic phase-sequence correction, so the installer does not normally need to exchange two phase wires manually when the incoming sequence is reversed.

✔ Q2: Does the motor have automatic phase-sequence correction?

Yes. The control system detects the incoming three-phase sequence and automatically corrects the phase direction required for motor operation.

✔ Q3: What controller is supplied with the motor?

The standard control package includes the FJK-M-QL06 Fireproof Rolling Controller, together with electronic limit control, dual manual control stations, backup battery, and flexible metal conduit hose.

✔ Q4: Can the motor connect to a building fire alarm system?

Yes. The controller can receive the required signal from a compatible Fire Alarm Control Panel (FACP) or firefighting control system. The exact signal interface should be confirmed according to the building’s fire control design.

✔ Q5: Can this motor be used for double-track double-curtain fire shutters?

Yes. The motor can be configured for double-track, double-curtain fire shutter systems. The actual motor arrangement should be checked against the curtain weight, door dimensions, and mechanical structure before production.

Ready to Order or Request Technical Drawings?

Contact ANLIN sales & engineering team for technical evaluations, OEM options, and volume pricing.

Inquiry

Interested in "Industrial Fireproof Rolling Door Motor for Fire Rated Shutters"? Fill out the form below and our team will get back to you shortly.